Phenolic Insulation
Specification
Physical Properties
Data Sheet (PDF)
MSDS
Approvals and Compliance
Recommended Thicknesses
Installation
 


NEWS RELEASE!

Dyplast Products announces its DyTherm Phenolic Insulation and DyPerm Vapor Barriers

DyTherm Phenolic Pipe Insulation Physical Properties

PHENOLIC INSULATION: RIGID FOAM PIPE INSULATION AND EQUIPMENT INSULATION

Download DyTherm Phenolic physical properties in .pdf version | .xls version | .doc version


Property

Test Method

Unit

Typical Values

Nominal Density

ASTM D1622

lb/ft3

2.5

3.75

5.0

7.5

Thermal Conductivity at +50°F

ASTM C518 (initial)

Btu·in/hr·ft² ·°F

0.145

0.17

0.21

0.222

Closed Cell Content

ASTM D2856 Method B

%

 95

95

95

95

Operating Temperature Upper Limit

 

°F

+248

+248

+248

+248

Operating Temperature Lowe r Limit

 

°F

–292

–292

–292

–292

Minimum Compressive Strength at +73°F

ASTM D1621

 

 

 

 

 

 

Parallel

Psi

29

58

90

150

 

Perpendicular

Psi

17.5

43

70

110

Minimum Tensile Strength at +73°F

ASTM D1623

 

 

 

 

 

 

Parallel

Psi

29

54

85

130

 

Perpendicular

Psi

26

41

65

100

Linear Dimensional Stability

ASTM D2126

 

 

 

 

 

 

+199.4°F for 24 hour

%

TBD

TBD

TBD

TBD

 

–22°F for 24 hours

%

TBD

TBD

TBD

TBD

Linear Expansion Coefficient

ASTM D696

ft/ft·K

TBD

TBD

TBD

TBD

Color

 

 

Gray

Gray

Gray

Gray

Surface Burning Characteristics

ASTM E84

 

 

 

 

 

 

Flame Spread @ 4 in thick

5

 

 

 

 

 

Smoke Density @ 4 in thick

0

 

 

 

 

 

MAIN TABLE Footnotes:

1. All properties are measured at 70°F – 75°+ unless otherwise indicated.
2. These are nominal values obtained from representative product samples, and are subject to normal manufacturing variances.
3. Average value through the foam cross section of tested sample.
4. Frequent and severe thermal cycling can produce dimensional changes significantly greater than those listed here. Special design considerations must be made in systems subject to severe cycling.
5. This numerical flame spread data is not intended to reflect hazards presented by this or any other material under actual fire conditions. FITNESS FOR USE MUST BE DETERMINED BY BUYER AND ENGINEER; DYPLAST PRODUCTS DOES NOT WARRANT FITNESS FOR USE.
_______________________________________________________________________________________________
FOR TECHNICAL INFORMATION:
(800) 433-5551 · Contact: Michael Cartmell
insulation@dyplast.info · VP Technology
www.dyplastproducts.com · Phone: (305) 921-0123 Fax: (305) 687-6353
12501 N.W. 38 th Ave. · Email: mcartmell@dyplastproducts.com
Miami, FL 33054 · MSDS sheets available upon request
NOTICE: No freedom from any patent owned by Dyplast Products or others is to be inferred. Because use conditions and applicable laws may differ from one location to another and may change with time, Customer is responsible for determining whether products and the information in this document are appropriate for Customer’s use and for ensuring that Customer’s workplace and disposal practices are in compliance with applicable laws and other government enactments. Dyplast Products assumes no obligation or liability for the information in this document. NO WARRANTIES ARE GIVEN; ALL IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ARE EXPRESSLY EXCLUDED.
LIMITATIONS AND DISCLAIMER OF WARRANTIES AND LIABILITIES
Characteristics, properties, performance of materials, and application specifications herein described are based on data obtained under controlled conditions. Information is supplied upon the condition that the persons receiving same will make their own determination as to its suitability for their purposes prior to use. Dyplast Products makes no implied warranties of any type, including without limitation, any warrant of merchantability or fitness of purpose. In no event will Dyplast Products be responsible for damages of any nature whatsoever resulting from the use of or reliance upon this information or the product to which information refers. No agent, sales representative, or employee is empowered to change, alter, or amend this provision, unless approved in writing by a duly authorized officer of Dyplast Products.