GeoFoam (Expanded Polystyrene) Rigid Foam

Typical Physical Properties

Jump to: EPS Insulation | Architectural Shapes | Holey-Board |

Download this Document: .pdf version

>

Specification Reference: ASTM C578-10, ASTM D1621-04, and ASTM D6817-07

PROPERTY

UNITS

ASTM Test

EPS 15

EPS 19

EPS 22

EPS 29

Density, minimum lb/ft3 D 303 or
D 1622
0.90 1.15 1.35 1.80
Density Range  lb/ft3   0.90 - 1.14 1.15-1.34 1.35-1.79 1.80-2.20
Compressive 1% Deformation: (Minimum*) lb/in2 D 1621 >3.6 >5.8

>7.30

>13.00

Compressive 5% Deformation: Actual (Minimum) lb/in2 D 1621 >8.0 >13.1

>21.50

>26.50

Compressive 10% Deformation: Actual (Minimum) lb/in2 D 1621 >10.2 >16.0

>24.20

>29.70

Flexural Strength lb/in2 C 203 >25.0 >30.0 >40.0 >50.0
Modulus of Elasticity lb/in2 --- 360 580 730 1090
Water Absorption (vol.) % C 272 < 4.0 < 3.0 < 3.0 < 2.0
Oxygen Index % D 2863 24.0 24.0 24.0 24.0

* "minimum" for GeoFoam per ASTM D6817