ISO-C1 POLYISOCYANURATE RIGID FOAM INSULATION SERIES 200 (2 lb. density)

Physical Properties 1

 

ASTM Method

English Units 2

Metric Units 2

Density 3

D 1622

2.1

lb/ft 3

33.71

kg/m 3

Compressive Strength 3

D 1621

 

 

 

 

 

Parallel to Rise (Thickness)

 

25.9

lb/in 2

178.2

kPa

 

Perpendicular to Rise (Width)

 

29.4

lb/in 2

202

kPa

Shear Strength: Parallel and Perpendicular

C 273

27.13

lb/in 2

187

kPa

Shear Modulus

C 273

346

lb/in 2

2385

kPa

Tensile Strength: Parallel and Perpendicular

D 1623

32.5

lb/in 2

224.3

kPa

Flexural Strength: Parallel and Perpendicular

C 203

54

lb/in 2

372

kPa

Flexural Modulus

C 203

864

lb/in 2

5952

kPa

Closed Cell Content

D 2856

>90

%

>90

%

Buoyancy

 

60

lb/ft 3

961

kg/m 3

Water Absorption

C 272

0.24

% by volume

0.24

% by volume

Water Vapor Permeance

E 96

2.33

perm-inch

3.42

ng/Pa·s·m

Service Temperature 3

 

-297 to +300

°F

-183 to +149

°C

Dimensional Stability 4,5

D 2126

 

 

 

 

 

@ -40°F (-40°C), 7 days: Length

< -0.1

% Change

< -0.1

% Change

 

Volume

< -0.1

% Change

< -0.1

% Change

 

@ 158°F (70°C)/97% RH, 7 days: Length

<+1.0

% Change

<+1.0

% Change

 

Volume

<+2.0

% Change

<+2.0

% Change

 

@ 212°F (100°C), 7 days: Length

<+0.6

% Change

<+0.6

% Change

 

Volume

<+1.0

% Change

<+1.0

% Change

Thermal Resistance

C 518

 

 

 

 

 

10 days K-Factor

C 518

0.15 Initial

 

0.022 Initial

W/m·°C

 

K-Factor (aged)

C 518

0.19

BTU ·in/hr·

ft 2·°F

0.03

W/m·°C

 

R-Factor (@ 1" aged)

C 518

5.26

hr·ft 2·°F/

BTU

0.94

m 2·°C/W

Surface Burning Characteristics 6

 

UL Rating

 

FM Rating

 

 

Flame Spread @ 4" (10 cm)

E 84

25

 

25

 

 

Smoke Density @ 4" (10cm)

E 84

195

 

130

 

 

Hot Surface

C 411

Pass

 

Pass

 

 

MAIN TABLE Footnotes:

 

 

 

 

 

1. All properties are measured at 70°F – 75°+ unless otherwise indicated and all test values from independent certified testing laboratories.

2. These are nominal values obtained from representative product samples, and are subject to normal manufacturing variances.

3. Average value through the foam cross section.

 

 

 

4.   Above 300°F, discoloration and charring will occur, resulting in an increased K-Factor in the discolored area.

5. Frequent and severe thermal cycling can produce dimensional changes significantly greater than those listed here. Special design considerations must be made in systems subject to severe cycling.

6. This numerical flame spread data is not intended to reflect hazards presented by this or any other material under actual fire conditions.

 

See Contact Information, Notices, and Limitations on the following page
_______________________________________________________________________

 

 

 

 

FOR TECHNICAL INFORMATION:

 

(800) 433-5551

 

 

· Contact: Esmeralda Martinez

 

insulation@dyplast.info

 

 

Technical Director

 

 

www.dyplastproducts.com

 

 

· Phone: (305) 921-0123 Fax: (305) 687-6353

 

12501 N.W. 38 th Ave.

 

 

· Email: emartinez@dyplastproducts.com

 

Miami, FL 33054

 

 

· MSDS sheets available upon request

 

 

 

 

 

 

 

 

NOTICE: No freedom from any patent owned by Dyplast Products or others is to be inferred. Because use conditions and applicable laws may differ from one location to another and may change with time, Customer is responsible for determining whether products and the information in this document are appropriate for Customer’s use and for ensuring that Customer’s workplace and disposal practices are in compliance with applicable laws and other government enactments. Dyplast Products assumes no obligation or liability for the information in this document. NO WARRANTIES ARE GIVEN; ALL IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ARE EXPRESSLY EXCLUDED.

 

 

 

 

 

 

 

 

LIMITATIONS AND DISCLAIMER OF WARRANTIES AND LIABILITIES

 

 

Characteristics, properties, performance of materials, and application specifications herein described are based on data obtained under controlled conditions. Information is supplied upon the condition that the persons receiving same will make their own determination as to its suitability for their purposes prior to use. Dyplast Products makes no implied warranties of any type, including without limitation, any warrant of merchantability or fitness of purpose. In no event will Dyplast Products be responsible for damages of any nature whatsoever resulting from the use of or reliance upon this information or the product to which information refers. No agent, sales representative, or employee is empowered to change, alter, or amend this provision, unless approved in writing by a duly authorized officer of Dyplast Products.