Foam III Typical Physical Properties Polyisocyanurate Insulation

Polyisocyanurate Roof Insulation Panels for Hot Applications

HCFC Free "Green"Roof Insulation: Polyisocyanurate core integrally laminated to heavy coated- glass felt facers

Download This Spec: .pdf version | .xls version | .doc version

PROPERTY

TEST METHOD

TYPICAL RESULTS
ASTM D 2126 < 2 %
Dimensional Stability (Length and Width)
Compressive Strength (10% Deformation) ASTM D 1621 20 lb/ft2

140 kPa

Water Absorption ASTM C 209

ASTM D 2842

< 1 %

< 3.5 %

Moisture Vapor Transmission ASTM E 96 < 1.5 perm

85.0 ng/(Pa·s·m2)

Product Density ASTM D 1622 2.0 lb/ft3 Nominal
Flame Spread ASTM E 84 (Full 10 min. Test) 25-50**
Smoke Developed ASTM E 84 (Full 10 min. Test) 50-170**
Tensile Strength ASTM D 1623 > 730 lb/ft2

> 35 kPa

Service Temperature - -100 to 250 ºF

-73 to 122 ºC

* The physical properties listed above are presented as typical average values as determined by accepted ASTM test methods and are subject to normal manufacturing variation. This data is offered as a service to our customers and is subject to change.

** The numerical ratings as determined by ASTM Test Method E 84 are not intended to reflect hazards presented by this or any other material under actual fire conditions. A flame spread index of 75 or less meets code requirements regarding flame spread for foam plastic roof insulation. However, flame spread values are not required for foam plastic insulation used in roof deck constructions that comply as an assembly with FM 4450 or UL 1256 (see IBC, BOCA, SBCCI, and ICBO model building codes, Chapter 26). Smoke Developed values do not apply to roofing.